Analisis Akurasi Termometer Inframerah Non-Kontak dan Rancangan Konseptual Sistem Koreksi Multiparameter
Abstract
This study aims to examine the working principles of non-contact infrared thermometers (NCITs), identify the factors that affect the accuracy of body temperature measurement, and propose a conceptual design for a smart infrared thermometer based on environmental correction and multi-parameter analysis. The study used an integrative literature review with a descriptive-comparative approach, drawing on clinical studies, systematic reviews, meta-analyses, and previous research on technologies developed to improve NCIT accuracy. The data reviewed included measurement bias, sensitivity, specificity, measuring distance, environmental conditions, sensor characteristics, and compensation methods. These findings were extracted and compared to identify the main sources of inaccuracy and to determine the components needed in the proposed system. The synthesis shows that measurement differences tend to increase as the distance between the device and the forehead becomes greater. Environmental factors such as wind, sweat, sunlight exposure, ambient temperature, and humidity may also alter skin surface temperature without accurately representing core body temperature. In addition, NCITs generally show higher specificity than sensitivity, which may increase the risk of false-negative results in febrile individuals. Based on these findings, the proposed system integrates an infrared sensor, distance sensor, ambient temperature and humidity sensors, a microcontroller, and a multi-parameter compensation algorithm to correct raw data and estimate measurement uncertainty. In conclusion, conventional NCITs are more suitable for initial screening, while the proposed multisensor system may improve measurement consistency and reliability, although prototype development, standard calibration, and experimental testing are still required
ABSTRAK
Penelitian ini bertujuan menganalisis prinsip kerja termometer inframerah non-kontak (Non-Contact Infrared Thermometer/NCIT), mengidentifikasi faktor-faktor yang memengaruhi akurasi pengukuran suhu tubuh, serta merumuskan rancangan konseptual termometer inframerah cerdas berbasis koreksi lingkungan dan analisis multiparameter. Penelitian dilakukan melalui kajian literatur integratif dengan pendekatan deskriptif-komparatif terhadap hasil uji klinis, kajian sistematis, meta-analisis, dan penelitian mengenai teknologi peningkat akurasi NCIT. Data yang dianalisis mencakup bias pengukuran, sensitivitas, spesifisitas, jarak pengukuran, kondisi lingkungan, karakteristik sensor, serta metode kompensasi. Data tersebut diekstraksi dan dibandingkan untuk mengidentifikasi sumber ketidakakuratan sekaligus menentukan komponen yang diperlukan dalam rancangan sistem. Hasil sintesis menunjukkan bahwa selisih pengukuran cenderung meningkat ketika jarak alat dari dahi bertambah. Selain itu, angin, keringat, paparan sinar matahari, suhu, dan kelembapan lingkungan dapat mengubah suhu permukaan kulit tanpa selalu mencerminkan suhu inti tubuh. Nilai spesifisitas NCIT juga cenderung lebih tinggi daripada sensitivitasnya, sehingga terdapat risiko negatif palsu pada individu yang mengalami demam. Berdasarkan temuan tersebut, diusulkan Sistem Termometer Inframerah Cerdas Berbasis Koreksi Lingkungan dan Analisis Multiparameter yang mengintegrasikan sensor inframerah, sensor jarak, sensor suhu dan kelembapan, mikrokontroler, serta algoritma kompensasi untuk mengoreksi data mentah dan memperkirakan ketidakpastian pengukuran. Dapat disimpulkan bahwa NCIT konvensional lebih tepat digunakan sebagai alat skrining awal, sedangkan rancangan multisensor yang diusulkan berpotensi meningkatkan konsistensi dan keandalan hasil pengukuran, meskipun masih memerlukan pengembangan prototipe, kalibrasi standar, dan pengujian eksperimental.
References
Aggarwal, N., et al. (2020). Diagnostic accuracy of non-contact infrared thermometers and thermal scanners: systematic review and meta-analysis. Journal of Travel Medicine, 27(8), Article taaa193. https://doi.org/10.1093/jtm/taaa193
Cross, E. L. A., McMullan, J., Carland, J., Kelly, C., Gibbons, T., & Doughty, H. (2025). Comparing thermal imaging and non-contact infrared thermometers for skin temperature assessment. BMJ Open, 15(1), Article e089621. https://doi.org/10.1136/bmjopen-2024-089621
Goh, N. W. J., et al. (2021). Design and development of a low cost, non-contact infrared thermometer with range compensation. Sensors, 21(11), Article 3817. https://doi.org/10.3390/s21113817
Holder, T., Wilson, R., Williams, M., & Clarke, J. (2024). Clinical accuracy of infrared temperature measurement devices: A comparison against non-invasive core-body temperature. Clinical Medicine, 24(2), 100–108. https://doi.org/10.1016/j.clinme.2024.100108
Kim, Y. M., Lee, J. H., Park, S. H., & Choi, H. J. (2022). Clinical accuracy of non-contact forehead infrared thermometer measurement in children: An observational study. Children, 9(9), Article 1389. https://doi.org/10.3390/children9091389
Lee, K. C., Chen, Y. T., Lin, P. H., & Huang, C. Y. (2025). The impact of age on comparative diagnostic accuracy of non-contact infrared thermometers: A systematic review and meta-analysis. BMC Infectious Diseases, 25, Article
112. https://doi.org/10.1186/s12879-025-10212-y
Razmara, P., Ghasemi, A., & Karimi, M. (2024). Fever detection with infrared thermography: Enhancing accuracy through machine learning techniques. Journal of Thermal Biology, 119, Article 103780. https://doi.org/10.1016/j.jtherbio.2024.103780
Sullivan, S. J. L., Rinaldi, J. E., Hariharan, N., Casamento, J. P., Baek, S. Y., Seay, N. W., & Coles, C. L. (2021). Clinical evaluation of non-contact infrared thermometers. Canadian Journal of Public Health, 112(5), 789–796. https://doi.org/10.17269/s41997-021-00546-5
Sullivan, S. J. L., et al. (2021). Clinical evaluation of non-contact infrared thermometers. Scientific Reports, 11, Article 22079. https://doi.org/10.1038/s41598-021-01645-w
Tong, Y., Li, X., Zhang, W., & Liu, H. (2021). A hybrid method for overcoming thermal shock of non-contact infrared thermometers. arXiv. https://doi.org/10.48550/arXiv.2104.01234
Wang, Q., Zhang, Y., Li, J., & Chen, X. (2021). Infrared thermography for measuring elevated body temperature: Clinical accuracy, calibration, and evaluation. Sensors, 22(1), Article 215. https://doi.org/10.3390/s22010215
Zhao, Y., Wang, H., Liu, X., Zhang, Q., & Li, P. (2023). Non-contact infrared thermometers and thermal scanners for human body temperature monitoring: A systematic review. Sensors, 23(17), Article 7439. https://doi.org/10.3390/s23177439
Zhou, L., Chen, X., Wang, Y., & Huang, Z. (2024). Diagnostic accuracy of non-contact infrared thermometers for fever screening: A systematic review and meta-analysis. International Journal of Environmental Research and Public Health, 21(4), Article 512. https://doi.org/10.3390/ijerph21040512
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Proceedings of Castle

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.